Secondary Double Glazing Surveying Instructions |
 |
| |
Important information regarding our Secondary glazing and double glazing
Important Note:
These instructions are for general
guidance only and you should satisfy yourself
that they will apply to your situation.
***Please Read***
Within a very short period you will receive your invoice,
this also doubles as confirmation of your order.
When placing your order/quote we highly recommend
that you use the formulas laid out on this web page.
Failure to use these formulae can lead to mis-interpretation
of your requirements and we will not be responsible
for any problems that may arise as a result of not
following our guidelines.
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
NOTE:
We recommend you allow 10mm clearance
to allow for out of square reveals for ease of installation,
manufacturing and measuring tolerences. You may wish
to allow less than 10mm but this may mean you will
require a plane or sharp chisel. If in any doubt please
ask, we are here to help.
If your windows are less than 800mm
from the internal floor or within 300mm of a door
you will need toughened or laminated safety glass
at extra cost, this is to comply with Building
Regulations and is vitally important, if
in doubt please ask, as we are here to help you.
We offer full and unlimited telephone support
starting with the measuring procedure and including
help during the actual installation.
During the measuring process we can offer assistance
usually aided with digital images and/or sketches
provided by yourself
THIS IS A LONG PAGE PLEASE SCROLL DOWN FOR DIAGRAMS |
|
 |
Hinged Units |
 |
| |
Hinged unit left
Left Hung Opening In
Hinged unit Right
Right Hung Opening In
|
| 1. |
|
Take the overall size from wall B to wall C and minus 10mm, i.e. 600mm becomes 590mm |
| 2. |
|
Measure from wall A to wall C and minus 10mm |
When ordering, make sure you quote either: HUL or HUR
| 1. |
|
Take the overall size from wall B to wall C and minus 10mm, i.e. 600mm becomes 590mm |
| 2. |
|
Measure from wall A to wall C and minus 10mm |
When ordering, make sure you quote either: HUL or HUR
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
Equal 2 Panel Horizontal Slider |
 |
| |

|
| 1. |
|
Take the overall size from wall B to wall D and minus 10mm, i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from the wall to the centre of C and minus 5mm i.e. 890 becomes 885mm |
| 3. |
|
Measure from C to wall D and minus 5mm |
| 4. |
|
Measure from wall A to wall D and minus 10mm |
PLEASE NOTE: BOTH PANELS SLIDE
When ordering,
make sure you quote SS2
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
Unequal 2 Panel Horizontal Slider |
 |
| |
 |
| 1. |
|
Take the overall size from wall B to wall D and minus 10mm, i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from the wall to the centre of C and minus 5mm i.e. 890 becomes 885mm |
| 3. |
|
Measure from C to wall D and minus 5mm |
| 4. |
|
Measure from wall A to wall D and minus 10mm |
PLEASE NOTE: BOTH PANELS SLIDE
When ordering,
make sure you quote either: SS2
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
Equal
3 Panel Horizontal Slider |
 |
| |

PLEASE NOTE: ONLY 2 PANELS SLIDE
When ordering, make sure you quote either: CO3 or SS3
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
| 1. |
|
Take the overall
size from wall B to wall E and minus 10mm,
i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from
the wall to the centre of C and minus
5mm i.e. 890 becomes 885mm |
| 3. |
|
Measure from
C to D - centre to centre to line up all
mullions |
| 4. |
|
Measure from
D to wall E and minus 5mm |
| 5. |
|
Measure from
wall A to wall E and minus 10mm |
|
|
|
 |
Unequal
3 Panel Horizontal Slider |
 |
| |
PLEASE NOTE: ONLY 2 PANELS SLIDE
When ordering, make sure you quote
either:
CO3 or SS3
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
| 1. |
|
Take the overall
size from wall B to wall E and minus 10mm,
i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from
the wall to the centre of C and minus
5mm i.e. 890 becomes 885mm |
| 3. |
|
Measure from
C to D - centre to centre to line up all
mullions |
| 4. |
|
Measure from
D to wall E and minus 5mm |
| 5. |
|
Measure from
wall A to wall E and minus 10mm |
|
|
|
 |
4
Panel Horizontal Slider |
 |
| |
| 1. |
|
Take the overall
size from wall B to wall F and minus 10mm,
i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from
wall B to the centre of C and minus 5mm
i.e 890mm becomes 885mm |
| 3. |
|
Measure from
C to D - (Centre to centre to line up all
mullions) |
| 4. |
|
Measure from Dto E- (Centre
to centre to line up all mullions) |
| 5. |
|
Measure from E to wall
F and minus 5mm |
| 6. |
|
Measure from wall A to wall
F and minus 10mm |
NOTE: CAN BE MADE TO EQUAL OR UNEQUAL PANEL SIZES
When ordering, make sure you quote: SS4
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
5
Panel Horizontal Slider |
 |
| |
| 1. |
|
Take the overall
size from wall B to wall G and minus 10mm,
i.e. 1780mm becomes 1770mm |
| 2. |
|
Measure from
wall B to the centre of C and minus 5mm
i.e 890mm becomes 885mm |
| 3. |
|
Measure from
C to D - (Centre to centre to line up all
mullions) |
| 4. |
|
Measure from Dto E- (Centre
to centre to line up all mullions) |
| 5. |
|
Measure from E to F- (Centre
to centre to line up all mullions) |
| 6. |
|
Measure from F to wall
G and minus 5mm |
| 7. |
|
Measure from wall A to wall
G and minus 10mm |
NOTE: CAN BE MADE TO EQUAL OR UNEQUAL PANEL SIZES
When ordering, make sure you quote: SS5
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
Balanced Vertical Slider or Tilt To Wash BVS |
 |
| |
Balanced Vertical
Slider
With Spring Balances 
BVS Offset Panels |
| 1. |
|
Measure from
wall D to wall C and minus 10mm |
| 2. |
|
Measure from
wall A to wall C and minus 10mm |
| 3. |
|
Measure from
wall A to the centre of B and minus 5mm |
When ordering, make sure you quote either: BVS or Tilt to Wash
| 1. |
|
Measure from
wall D to wall C and minus 10mm |
| 2. |
|
Measure from
wall A to wall C and minus 10mm |
| 3. |
|
Measure from
wall A to the centre of B and minus 5mm |
When ordering, make sure you quote: BVS or Tilt to Wash
Please do not include attachments with your email. All we require is your width and height sizes, styles and quantities. Please just write these in the body of your email.
|
|
|
 |
How do
I get a Quotation for Secondary Double Glazing? |
 |
| |
| In order to
obtain a quotation for secondary glazing you
need to email us with - widths
x heights x style (e.g. two panel vertical slider,
three panel horizontal slider, hinged unit etc)
as per the measuring instructions below
You would be well advised to have a good look
at the secondary glazing options available and
which of those suits your requirements for the
final operation of the products.
E-mail - 2013@secondaryglazing.com
If you require assistance call 01325
310520. Please Note: Quotations
are only available via e-mail,
however you can have as much technical advice
via telephone from our technical department,
who are always happy to help
|
|
|
Main Page | Quotations
| Ordering Information
| FAQ | Measuring
| Contact Us
|
|